WATERFLUX 3000 Range

The WATERFLUX 3000 range is a family of electromagnetic flow instruments for potable water, raw/ground/surface water and distribution networks. The range combines a patented rectangular sensor design, rugged Rilsan® liners (model-dependent), and no-straight-run installation to deliver stable measurement at low flow rates. Models span from a flow sensor for use with IFC converters to full flowmeters for basic, standard and custody-transfer water applications, including a battery-powered option for remote metering.

Models

  • WATERFLUX 3000 Electromagnetic flow sensor for combination with IFC 050, IFC 070, IFC 100 and IFC 300 flow converters.

  • WATERFLUX 3050 Electromagnetic flowmeter for basic water applications.

  • WATERFLUX 3070 Electromagnetic water meter for district metering of potable water and custody transfer (CT) measurement.

  • WATERFLUX 3100 Electromagnetic flowmeter for standard water applications.

  • WATERFLUX 3300 Electromagnetic flowmeter for advanced water and custody transfer (CT) applications.

  • Unique rectangular sensor design; no inlet/outlet runs required (0D/0D for 3070).
  • Robust Rilsan® coated measuring tube on 3050/3070/3100/3300.
  • Battery- or mains-powered operation available (3070).
  • Wide size range DN25…600 / 1…24″ with EN/ASME/JIS flanges; selected models also with male threads (G1, G1½, G2).
  • Communications from pulse/status to 4…20 mA, HART®, Modbus RTU, and (on 3300) FOUNDATION™ Fieldbus / Profibus-PA/DP / PROFINET.
  • Potable water approvals across models; marine and custody transfer approvals where specified.
  • Potable, ground and surface water measurement and distribution monitoring
  • Irrigation and abstraction
  • District metering (DMA) and remote water supply points (battery option)
  • Water treatment plants; checking of pumps and water wells
  • Custody transfer / fiscal metering in water networks (model-dependent)

Specifications

Depending on selected device configuration

Specification
WATERFLUX 3000
WATERFLUX 3050
WATERFLUX 3070
WATERFLUX 3100
WATERFLUX 3300
Product type
Flow component/auxiliary equipment
Flowmeter
Flowmeter
Flowmeter
Flowmeter
Product family name
WATERFLUX
WATERFLUX
WATERFLUX
WATERFLUX
WATERFLUX
Product positioning
For combination with IFC 050, IFC 070, IFC 100 and IFC 300 flow converters
For basic water applications
For district metering of potable water and custody transfer (CT) measurement
For standard water applications
For advanced water and custody transfer (CT) applications
Measurement principle
Electromagnetic
Electromagnetic
Electromagnetic
Electromagnetic
Electromagnetic
Measured media
N/A
Liquids
Liquids
Liquids
Liquids
Process pressure
N/A
max. 16 barg/ 230 psig
max. 16 barg/ 230 psig
max. 16 barg/ 230 psig
max. 16 barg/ 230 psig
Process temperature
N/A
5…+70°C/ +23…+158°F
5…+70°C/ +23…+158°F
5…+70°C/ +23…+158°F
5…+70°C/ +23…+158°F
Liner
N/A
Polyamide polymer 11 (Rilsan®)
Polyamide polymer 11 (Rilsan®)
Polyamide polymer 11 (Rilsan®)
Polyamide polymer 11 (Rilsan®)
Flange connections
N/A
EN (1092-1): DN25…600 • ASME (B 16.5): 1…24" • JIS (B 2220): 25…600A
EN (1092-1): DN25…600 • ASME (B 16.5): 1…24" • JIS (B 2220): 25…600A
EN (1092-1): DN25…600 • ASME (B 16.5): 1…24" • JIS (B 2220): 25…600A
EN (1092-1): DN25…600 • ASME (B 16.5): 1…24" • JIS (B 2220): 25…600A
Thread connections
N/A
Male: G1, G1½, G2
Male: G1, G1½, G2
Male: G1, G1½, G2
Male: G1, G1½, G2
Installation – Inlet run
N/A
N/A
0D
N/A
N/A
Installation – Outlet run
N/A
N/A
0D
N/A
N/A
Certificates/Approvals Custody transfer (CT)
N/A
N/A
N/A
N/A
MI-001, MI-004, OIML R49
Certificates/Approvals Marine
N/A
ABS, BV, CCS, DNV, KR, LR, NK, RINA, CRS, IRS, PRS, RS
N/A
ABS, BV, CCS, DNV, KR, LR, NK, RINA, CRS, IRS, PRS, RS
ABS, BV, CCS, DNV, KR, LR, NK, RINA, CRS, IRS, PRS, RS
Certificates/Approvals Potable Water
N/A
DVGW, NSF, TZW, KTW, WRAS, KIWA, ACS
DVGW, NSF, TZW, KTW, WRAS, KIWA, ACS
DVGW, NSF, TZW, KTW, WRAS, KIWA, ACS
DVGW, NSF, TZW, KTW, WRAS, KIWA, ACS
Analogue outputs
N/A
4…20 mA
N/A
4…20 mA
4…20 mA
Discrete outputs
N/A
Pulse, Frequency, Status
Pulse, Status
Pulse, Frequency, Status
Limit switches, Pulse, Frequency, Status
Digital outputs
N/A
HART®, Modbus RTU
Modbus RTU
HART®
FOUNDATION™ Fieldbus, HART®, Profibus-PA, Profibus-DP, Modbus RTU, PROFINET
SpecificationWATERFLUX 3000WATERFLUX 3050WATERFLUX 3070WATERFLUX 3100WATERFLUX 3300
Product typeFlow component/auxiliary equipmentFlowmeterFlowmeterFlowmeterFlowmeter
Product family nameWATERFLUXWATERFLUXWATERFLUXWATERFLUXWATERFLUX
Product positioningFor combination with IFC 050, IFC 070, IFC 100 and IFC 300 flow convertersFor basic water applicationsFor district metering of potable water and custody transfer (CT) measurementFor standard water applicationsFor advanced water and custody transfer (CT) applications
Measurement principleElectromagneticElectromagneticElectromagneticElectromagneticElectromagnetic
Measured mediaN/ALiquidsLiquidsLiquidsLiquids
Process pressureN/Amax. 16 barg/ 230 psigmax. 16 barg/ 230 psigmax. 16 barg/ 230 psigmax. 16 barg/ 230 psig
Process temperatureN/A5…+70°C/ +23…+158°F5…+70°C/ +23…+158°F5…+70°C/ +23…+158°F5…+70°C/ +23…+158°F
LinerN/APolyamide polymer 11 (Rilsan®)Polyamide polymer 11 (Rilsan®)Polyamide polymer 11 (Rilsan®)Polyamide polymer 11 (Rilsan®)
Flange connectionsN/AEN (1092-1): DN25…600 • ASME (B 16.5): 1…24" • JIS (B 2220): 25…600AEN (1092-1): DN25…600 • ASME (B 16.5): 1…24" • JIS (B 2220): 25…600AEN (1092-1): DN25…600 • ASME (B 16.5): 1…24" • JIS (B 2220): 25…600AEN (1092-1): DN25…600 • ASME (B 16.5): 1…24" • JIS (B 2220): 25…600A
Thread connectionsN/AMale: G1, G1½, G2Male: G1, G1½, G2Male: G1, G1½, G2Male: G1, G1½, G2
Installation – Inlet runN/AN/A0DN/AN/A
Installation – Outlet runN/AN/A0DN/AN/A
Certificates/Approvals Custody transfer (CT)N/AN/AN/AN/AMI-001, MI-004, OIML R49
Certificates/Approvals MarineN/AABS, BV, CCS, DNV, KR, LR, NK, RINA, CRS, IRS, PRS, RSN/AABS, BV, CCS, DNV, KR, LR, NK, RINA, CRS, IRS, PRS, RSABS, BV, CCS, DNV, KR, LR, NK, RINA, CRS, IRS, PRS, RS
Certificates/Approvals Potable WaterN/ADVGW, NSF, TZW, KTW, WRAS, KIWA, ACSDVGW, NSF, TZW, KTW, WRAS, KIWA, ACSDVGW, NSF, TZW, KTW, WRAS, KIWA, ACSDVGW, NSF, TZW, KTW, WRAS, KIWA, ACS
Analogue outputsN/A4…20 mAN/A4…20 mA4…20 mA
Discrete outputsN/APulse, Frequency, StatusPulse, StatusPulse, Frequency, StatusLimit switches, Pulse, Frequency, Status
Digital outputsN/AHART®, Modbus RTUModbus RTUHART®FOUNDATION™ Fieldbus, HART®, Profibus-PA, Profibus-DP, Modbus RTU, PROFINET

Related Prodcuts

The OPTIFLUX 4000 range of electromagnetic flowmeters is designed to meet a variety of application needs – from auxiliary equipment to basic, standard, advanced, and safety-critical measurement tasks. Each model offers reliable performance, high accuracy, and robust construction, making them suitable for demanding industries and environments.