OPTIFLUX 2000 Range

The OPTIFLUX 2000 range offers reliable electromagnetic flowmeters designed for water and wastewater applications. From basic installations to advanced custody transfer, the range ensures dependable performance, accuracy, and compliance with international standards.

Models

  • OPTIFLUX 2000 Flow component for use with IFC signal converters

  • OPTIFLUX 2050 For basic water and wastewater applications

  • OPTIFLUX 2100 For standard water and wastewater applications

  • OPTIFLUX 2300 For advanced water, wastewater and custody transfer (CT)

  • Electromagnetic measurement principle with no moving parts
  • Wide range of process connections (EN, ASME, JIS)
  • Multiple liner materials for versatility
  • Certified for potable water and marine use (model dependent)
  • Ex and custody transfer approvals available on higher-end models
  • Flexible communication options including analogue, discrete, and digital outputs
  • Water distribution networks
  • Wastewater treatment plants
  • Custody transfer in the water industry
  • Marine and offshore water measurement
  • Utility and infrastructure flow monitoring

Specifications

Depending on selected device configuration

Specification
OPTIFLUX 2000
OPTIFLUX 2050
OPTIFLUX 2100
OPTIFLUX 2300
Product type
Flow component / auxiliary equipment
Flowmeter
Flowmeter
Flowmeter
Product family name
OPTIFLUX
OPTIFLUX
OPTIFLUX
OPTIFLUX
Product positioning
For combination with IFC 050, IFC 100, IFC 300
Basic water & wastewater applications
Standard water & wastewater applications
Advanced water, wastewater & custody transfer (CT)
Measurement principle
Electromagnetic
Electromagnetic
Electromagnetic
Electromagnetic
Measured media
N/A
Liquids
Liquids
Liquids
Process pressure
N/A
max. 40 barg / 580 psig
max. 40 barg / 580 psig
max. 40 barg / 580 psig
Process temperature
N/A
5…+90 °C / +23…+194 °F
5…+90 °C / +23…+194 °F
5…+90 °C / +23…+194 °F
Liner
N/A
Polypropylene (PP), Hard rubber
Polypropylene (PP), Hard rubber
Polypropylene (PP), Hard rubber
Process connections
N/A
EN (DN25…1200), ASME (1…48"), JIS (25…1000A)
EN (DN25…1200), ASME (1…48"), JIS (25…1000A)
EN (DN25…3000), ASME (1…120"), JIS (25…1000A)
Approvals Ex
N/A
N/A
ATEX, IECEx, NEPSI, FM, CSA
ATEX, cQPSus, IECEx, NEPSI, EAC Ex, INMETRO, FM, CSA, KCs, PESO, IA
Approvals – Custody Transfer (CT)
N/A
N/A
N/A
MI-001, OIML R49
Approvals – Marine
N/A
ABS, BV, CCS, DNV, KR, LR, NK, RINA, CRS, IRS, PRS, RS
ABS, BV, CCS, DNV, KR, LR, NK, RINA, CRS, IRS, PRS, RS
ABS, BV, CCS, DNV, KR, LR, NK, RINA, CRS, IRS, PRS, RS
Approvals – Potable Water
N/A
DVGW, NSF, TZW, KTW, WRAS, KIWA, ACS
DVGW, NSF, TZW, KTW, WRAS, KIWA, ACS
DVGW, NSF, TZW, KTW, WRAS, KIWA, ACS
Analogue outputs
N/A
4…20 mA
4…20 mA
4…20 mA
Discrete outputs
N/A
Pulse, Frequency, Status
Pulse, Frequency, Status
Limit switches, Pulse, Frequency, Status
Digital outputs
N/A
HART®, Modbus RTU
HART®
FOUNDATION™ Fieldbus, HART®, Profibus-PA, Profibus-DP, Modbus RTU, PROFINET
SpecificationOPTIFLUX 2000OPTIFLUX 2050OPTIFLUX 2100OPTIFLUX 2300
Product typeFlow component / auxiliary equipmentFlowmeterFlowmeterFlowmeter
Product family nameOPTIFLUXOPTIFLUXOPTIFLUXOPTIFLUX
Product positioningFor combination with IFC 050, IFC 100, IFC 300Basic water & wastewater applicationsStandard water & wastewater applicationsAdvanced water, wastewater & custody transfer (CT)
Measurement principleElectromagneticElectromagneticElectromagneticElectromagnetic
Measured mediaN/ALiquidsLiquidsLiquids
Process pressureN/Amax. 40 barg / 580 psigmax. 40 barg / 580 psigmax. 40 barg / 580 psig
Process temperatureN/A5…+90 °C / +23…+194 °F5…+90 °C / +23…+194 °F5…+90 °C / +23…+194 °F
LinerN/APolypropylene (PP), Hard rubberPolypropylene (PP), Hard rubberPolypropylene (PP), Hard rubber
Process connectionsN/AEN (DN25…1200), ASME (1…48"), JIS (25…1000A)EN (DN25…1200), ASME (1…48"), JIS (25…1000A)EN (DN25…3000), ASME (1…120"), JIS (25…1000A)
Approvals ExN/AN/AATEX, IECEx, NEPSI, FM, CSAATEX, cQPSus, IECEx, NEPSI, EAC Ex, INMETRO, FM, CSA, KCs, PESO, IA
Approvals – Custody Transfer (CT)N/AN/AN/AMI-001, OIML R49
Approvals – MarineN/AABS, BV, CCS, DNV, KR, LR, NK, RINA, CRS, IRS, PRS, RSABS, BV, CCS, DNV, KR, LR, NK, RINA, CRS, IRS, PRS, RSABS, BV, CCS, DNV, KR, LR, NK, RINA, CRS, IRS, PRS, RS
Approvals – Potable WaterN/ADVGW, NSF, TZW, KTW, WRAS, KIWA, ACSDVGW, NSF, TZW, KTW, WRAS, KIWA, ACSDVGW, NSF, TZW, KTW, WRAS, KIWA, ACS
Analogue outputsN/A4…20 mA4…20 mA4…20 mA
Discrete outputsN/APulse, Frequency, StatusPulse, Frequency, StatusLimit switches, Pulse, Frequency, Status
Digital outputsN/AHART®, Modbus RTUHART®FOUNDATION™ Fieldbus, HART®, Profibus-PA, Profibus-DP, Modbus RTU, PROFINET

Related Prodcuts

The WATERFLUX 3000 range is a family of electromagnetic flow instruments for potable water, raw/ground/surface water and distribution networks. The range combines a patented rectangular sensor design, rugged Rilsan® liners (model-dependent), and no-straight-run installation to deliver stable measurement at low flow rates. Models span from a flow sensor for use with IFC converters to full flowmeters for basic, standard and custody-transfer water applications, including a battery-powered option for remote metering.
The OPTIFLUX 4000 range of electromagnetic flowmeters is designed to meet a variety of application needs – from auxiliary equipment to basic, standard, advanced, and safety-critical measurement tasks. Each model offers reliable performance, high accuracy, and robust construction, making them suitable for demanding industries and environments.
Compact, wafer-style electromagnetic meters and a matching sensor for straightforward to OEM-grade duties. The range balances easy installation, dependable accuracy and broad communications, making it a neat fit for water, utilities and packaged systems.